Use this feature to change the length of the timed signal or switch hook flash, generated by the system Recall feature (as well as by the Recall option used in Auto Dial and Speed Dial numbers). Recall sends this timed signal over the telephone line to the local telephone company or PBX to which the system is connected. Typically, you use the Recall feature to access a PBX, central office or Centrex feature, such as Call Waiting. Your local telephone company can tell you the correct setting—for most Centrex systems, the correct setting is 800 milliseconds.

You should change the default setting only under two conditions:

If using the system Recall feature has no effect, lengthen the time.

If the system is connected to a PBX and Recall drops calls, shorten the time.

 

1408/1416/9504/9508 Phone

1.At either of the first two extensions on the system, press Admin.

To do the above during a call, you may need to press the key phone PHONE button to display the Admin soft key option. If you access phone administration during a call, only the key speaker SPEAKER, key mute MUTE and key headset HEADSET buttons still affect the connected call.

2.Use the up arrow up or down down arrow arrow buttons to scroll the display to System Administration. When highlighted, press Select.

3.Use the up arrow up or down down arrow arrow buttons to scroll the display to System Parameters. When highlighted, press Select.

Alternatively, dial # and the system administration code.

4.Use the up arrow up or down down arrow arrow buttons to scroll the display to Recall timer. When highlighted, press Select.

5.The current setting is displayed.

6.Enter then option required between 01 and 80. Each step increases the timer by 25 milliseconds. Alternatively use the left arrow left or right right arrow arrow icons to toggle the settings or Default to return to the default setting (20 500msec).

Exit programming by pressing key phone PHONE. Alternatively use the Back button to move to another menu.

 

M7324/M7324N/M7310/M7310N/T7316/T7316E Phone

1.At either of the first two extensions on the system, press feature small Feature **config (ie. Feature **266344).

If the system has a system password set, it is requested. Enter the password.

2.The phone displays System Admin.

3.Enter two digits between 01 and 80. 01 is 25 milliseconds and 80 is 2000 milliseconds. Each number from 01 to 80 increases the timer by 25 milliseconds. Upon entry of the 2nd digit, the recall timer is updated. The default is 20 (500 milliseconds).

Alternatively use the Next Data or Previous Data buttons to change the setting or press Remove to return to the default setting.

To exit phone based administration at any time, press the Release button. To select a different process use the Next Procedure or Previous Procedure buttons or dial another feature code.

 

ETR 18D/ETR 34D Phone

1.At either or the first two extensions on the system, press Feature 0 0 followed by two presses of the first intercom or call appearance button.

2.System Administration: is shown on the display.

3.Dial #107. The phone will display Recall Timer Duration.

4.Enter two digits between 01 and 80. 01 is 25 milliseconds and 80 is 2000 milliseconds. Each number from 01 to 80 increases the timer by 25 milliseconds. Upon entry of the 2nd digit, the recall timer is updated.

Exit programming by pressing Feature 00. You can also exit programming mode by lifting the handset, then placing it back in the cradle.