IP Office Essential Edition - Basic Edition Phone Admin: Line Settings
Recall Timer Duration
Use this feature to change the length of the timed signal or switch hook flash, generated by the system Recall feature (as well as by the Recall option used in Auto Dial and Speed Dial numbers). Recall sends this timed signal over the telephone line to the local telephone company or PBX to which the system is connected. Typically, you use the Recall feature to access a PBX, central office or Centrex feature, such as Call Waiting. Your local telephone company can tell you the correct setting—for most Centrex systems, the correct setting is 800 milliseconds.
You should change the default setting only under two conditions:
•
If using the system Recall feature has no effect, lengthen the time.
•
If the system is connected to a PBX and Recall drops calls, shorten the time.
1408/1416/9404/9408/9504/9508 Phone
1.
At either of the first two extensions on the system, with the phone idle, press Admin.
2.
Use the up or down arrow buttons to scroll the display to System Administration. When shown, press Select.
3.
Use the up or down arrow buttons to scroll the display to System Parameters. When shown, press Select.
Use the up or down arrow buttons to scroll the display to Recall timer. When shown, press Select.
5.
The current setting is displayed.
6.
Enter then option required between 01 and 80. Each step increases the timer by 25 milliseconds. Alternatively use the left or right arrow icons to toggle the settings or Default to return to the default setting (20 500msec).
•
Exit programming by pressing PHONE/EXIT. Alternatively use the Back button to move to another menu.
M7324/M7324N/M7310/M7310N/T7316/T7316E Phone
1.
At either of the first two extensions on the system, with the phone idle, press Feature **config (ie. Feature **266344).
•
If the system has a system password set, it is requested. Enter the password.
2.
The phone displays System Admin.
3.
Enter two digits between 01 and 80. 01 is 25 milliseconds and 80 is 2000 milliseconds. Each number from 01 to 80 increases the timer by 25 milliseconds. Upon entry of the 2nd digit, the recall timer is updated. The default is 20 (500 milliseconds).
•
Alternatively use the Next Data or Previous Data buttons to change the setting or press Remove to return to the default setting.
•
To exit phone based administration at any time, press the Release button. To select a different process use the Next Procedure or Previous Procedure buttons or dial another feature code.
ETR 18D/ETR 34D Phone
1.
At either or the first two extensions on the system, with the phone idle, press Feature 0 0 followed by two presses of the first intercom or call appearance button.
2.
System Administration: is shown on the display.
3.
Dial #107. The phone will display Recall Timer Duration.
4.
Enter two digits between 01 and 80. 01 is 25 milliseconds and 80 is 2000 milliseconds. Each number from 01 to 80 increases the timer by 25 milliseconds. Upon entry of the 2nd digit, the recall timer is updated.
•
Exit programming by pressing Feature 00. You can also exit programming mode by lifting the handset, then placing it back in the cradle.
Performance figures, data and operation quoted in this document are typical and must be specifically confirmed in writing
by Avaya before they become applicable to any particular order or contract. The company reserves the right to
make alterations or amendments at its own discretion. The publication of information in this document does not
imply freedom from patent or any other protective rights of Avaya or others.
All trademarks identified by (R) or TM are registered trademarks or trademarks respectively of Avaya LLC. All other
trademarks are the property of their respective owners.