Connection
Connection of IP Office products must be via a Line Isolation Module with a telecommunications compliance label.
BRI Interface
During the configuration, ensure "000" emergency number is not barred, by performing the following:
•Short Code: 000
•Telephone No: 000;
•Function: DialEmergency
Connections to TS013, the following Bearer Capabilities shall not be used:
•7kHz Audio, Video, Restricted Digital Information.
If unknown type of number is used in calling party number, the network will use the default CLI.
The system must be configured for Point to Multi point connection to comply with Austel requirements for connecting to TS013 circuits.
As the IP Office does not support emergency dialing after loss of power, the following warning notice should be recognized:
•WARNING
This equipment will be inoperable when mains power fails.
PRI Interface
During the configuration, ensure "000" emergency number is not barred, by performing the following:
•Short Code: 000
•Telephone No: 000;
•Function: DialEmergency
•WARNING
This equipment will be inoperable during mains power failure.