The IP400 Analog Trunk module (also known as the ATM16) is used to add 16 additional analog trunks to an IP Office system. The module supports both loop-start and, with suitable grounding, ground-start trunks.

icon_warning WARNING
In all IP Office installations, any module being used for analog trunk connections must be connected to a functional earth.

icon_warning WARNING
Within the Republic of South Africa and in areas of high lightning risk, any module using analog trunk connections must be connected to a protective ground and to surge protection equipment.

atm16 3d large

Feature

Details

Locales

Specific variants are provided for different IP Office locales, see below.

Minimum Software Level

IP Office core software level 1.0 minimum. Bin file = naatm16.bin.

Included

Power supply unit (see below) and Expansion Interconnect cable.

Power Supply

The module is supplied with a 2-pin, 40W external power supply unit. The PSU has an integral power cord for connection to the module's DC I/P socket. A locale specific IEC60320 C13 power cord for the external PSU is required but is not supplied with the module.

Mounting

The module is designed as a free-standing module that can be stacked on or under other IP Office modules. The module can be rack mounted in a 19" rack system using the optional IP400 Rack Mounting Kit.

Dimensions

Width: 445mm/17.5". Depth: 245mm/9.7". Height: 71mm/2.8"/2U.

Weight

Unboxed: 2.9Kg/6.6lbs. Boxed: 4.2Kg/9.4lbs.

Module Front

atm16_v1_front

Module Rear

atm16_v1_rear

Ports

Description

ANALOG

RJ45 socket. Used for connection to analog trunks. Ports can be configured as either loop-start or ground-start trunks through the IP Office configuration.

In the event of power failure, Analog ports 1 and 2 are directly connected to analog extension ports PF1 and PF2 respectively. If used the connected phones must be clearly labeled as power failure devices. This is only supported for loop-start analog trunks.

DC I/P

DC power input port. Used for connection of the power lead from an Avaya 40W external power supply unit supplied with the expansion module. A locale specific IEC60320 C7 power cord for the external PSU is required but is not supplied with the module.

DTE

25-Way D-Type socket. For Avaya use only.

EXPANSION

RJ45 Socket. Used for direct connection to an Expansion port on an IP Office control unit using the Expansion Interconnect cable supplied with the module.

PF

RJ45 socket. Power failure analog extension ports. See Analog section above.

ground symbol

Ground point. Used for connection of a functional earth if required. On older modules where this screw is not present, the top-center cover screw should be used instead.

IMPORTANT
In all IP Office installations, any module being used for analog trunk connections must be connected to a functional earth.

icon_warning WARNING
Within the Republic of South Africa and in areas of high lightning risk, any module using analog trunk connections must be connected to a protective ground and to surge protection equipment.

Part Codes and Related Equipment

All expansion modules are supplied with a base software level and should be upgraded to match the core software of the control unit in the IP Office system. Expansion modules include an external power supply unit (PSU) and an appropriate interconnect cable. They do not include a locale specific power cord for the external PSU or any phone extension cables.

Item

Variant

Country

SAP Code

IP400 Analog Trunk 16

America

America

700211360

Europe

Europe

700241680

New Zealand

New Zealand

700241698

IEC60320 C7 Power Cord

plug ie60320 c7

CEE7/16

Europe

700213382

BS1363

United Kingdom

700213374

NEMA1-15

America

700213390

Korea

Korea

700254519

IP400 Rack Mounting Kit

All