The IP500 Analog Trunk module can be used to add 16 additional analog trunks to an IP Office system. The module supports both loop-start and, with suitable grounding, ground-start trunks.
•In IP Office Basic Edition modes, only 1 Analog Trunk module is supported.
• WARNING
In all IP Office installations, any module being used for analog trunk connections must be connected to a functional earth.
• WARNING
Within areas of high lightning risk, any module using analog trunk connections must be connected to a protective ground and to surge protection equipment.
Feature |
Details |
Locales |
This module is currently only supported in North American locales. |
Minimum Software Level |
IP Office core software level 1.0 minimum. Bin file = naatm16.bin. |
Included |
Power supply unit (see below) and Expansion Interconnect cable. |
Power Supply |
The module is supplied with a 2-pin, 40W external power supply unit. The PSU has an integral power cord for connection to the module's DC I/P socket. A locale specific IEC60320 C13 power cord for the external PSU is required but is not supplied with the module. |
Mounting |
The module is designed as a free-standing module that can be stacked on or under other IP Office modules. The module can be wall or rack mounted using the IPO IP500 RACK MNTG KIT V3. |
Dimensions |
Width: 445mm/17.5". Depth: 245mm/9.7". Height: 71mm/2.8"/2U. |
Weight |
Unboxed: 2.9Kg/6.6lbs. Boxed: 4.2Kg/9.4lbs. |
Module Front
Port LEDs |
None |
Module Center LED |
The center LED on all external expansion modules is used to indicate the overall state of the module as follows: •Red flashing = Module starting up/Loading firmware. •Red on = Error. •Green on = Module okay. |
Module Rear
Ports |
Description |
RJ45 socket. Used for connection to analog trunks. Ports can be configured as either loop-start or ground-start trunks through the IP Office configuration. In the event of power failure, Analog ports 1 and 2 are directly connected to analog extension ports PF1 and PF2 respectively. If used the connected phones must be clearly labeled as power failure devices. This is only supported for loop-start analog trunks. |
|
DC power input port. Used for connection of the power lead from an Avaya 40W external power supply unit supplied with the expansion module. A locale specific IEC60320 C7 power cord for the external PSU is required but is not supplied with the module. |
|
25-Way D-Type socket. For Avaya use only. |
|
RJ45 Socket. Used for direct connection to an Expansion port on an IP Office control unit using the Expansion Interconnect cable supplied with the module. |
|
RJ45 socket. Power failure analog extension ports. See Analog section above. |
|
Ground point. Used for connection of a functional earth if required. On older modules where this screw is not present, the top-center cover screw should be used instead. •IMPORTANT • WARNING |
Part Codes and Related Equipment
All expansion modules are supplied with a base software level and should be upgraded to match the core software of the control unit in the IP Office system. Expansion modules include an external power supply unit (PSU) and an appropriate interconnect cable. They do not include a locale specific power cord for the external PSU or any phone extension cables.
Item |
Variant |
Country |
SAP Code |
---|---|---|---|
IPO IP500 EXP MOD ANLG TRNK 16 |
America |
America |
700449473 |
IPO IP500 EXP MOD ANLG TRNK 16 TAA |
" Trade Agreements Act compliant variant. |
America |
700501511 |
IEC60320 C7 Power Cord |
NEMA1-15 |
America |
700213390 |
Mounting Kit |
IPO IP500 WALL MNTG KIT V3 |
All |
700503160 |