This card can be added to an IP500 base card to provide that card with support for BRI-To trunks. The card is available in 8 channel (4 physical trunks) or 4 channel (2 physical trunks) variants.

This card can be fitted to any non-combo IP500 base card except the IP500 4-Port Expansion card and Unified Communications Module.

ip500 bri card

Ports/Channels
2 or 4 BRI trunk ports. Connections via ports 9 to 12 of the host IP500 base card.

Each trunk port supports 2B+D channels.

ETSI or AusTS013 basic rate protocol set through the IP Office configuration.

License: No license required.

Maximum per Control Unit: 4.

Minimum Software Level: 4.0+.

S-Bus Connection: On IP Office 4.2+ systems, the card can be switched from To trunk mode to So mode. This mode requires additional terminating resistors and an ISDN crossover cable connection, see BRI Port (So).

This card is approved for use in the following countries: Argentina, Australia, Brazil, China, European Union (EU), India, New Zealand, Russia, South Africa, and United Arab Emirates (UAE).

 

port leds 9-12

Daughter Card Ports (9-12)
The LEDs for ports 9 to 12 of the IP500 base card are used as follows:

Off = No trunk present.

Green on = Trunk present.

Green flashing = Trunk in use.

LED 9 is also used for daughter card status.

Red On = Error

Red Slow Flash = Initializing.

Red Flash every 5 seconds = Card okay.

Red Fast Flash = System shutdown.

Name

Description

SAP Code

IPO 500 Trnk BRI 4 Uni

IP Office 500 Trunk Card Basic Rate 4 Universal

700417413

IPO IP500 TRNK BRI 4 UNI TAA

" Trade Agreements Act compliant variant.

700501515

IPO 500 Trnk BRI 8 Uni

IP Office 500 Trunk Card Basic Rate 8 Universal

700417421

IP0 IP500 BRI S0 CONVTR CBL

IP500 BRI So Converter Cable

700458649